Philips Ingenuity 128 CT Scanner

Philips Ingenuity 128 CT Scanner

Description

Philips Ingenuity 128 2014 System. Workstation Intellispace ISP SW Applications at the CT CT-Viewer Functional CT / Time Laps HeartBeat – CS CCA – Viewer Dual Monitor General Reporting Dynamic Viewer DVD – Ram Dicom Modality Worklist Retrospective Split Dose Log Viewer Reference Noise Show Tube Heat i Brain SW Applications on the ISP AVA BMD Comprehense Cardiac CCS Dental Lung Density Lung Nodule Assesment Virtual Colono Liver SPECIFICATIONS CT INGENUITY 128 NAME OF PRODUCT Multislice CT Scan 128 SLICE BRAND/ MANUFACTURER Philips MODEL / TYPE INGENUITY CORE 128 FACTORY OF ORIGIN PHILIPS HEALTHCARE (SUZHOU) Co.,Ltd,. CHINA Melalui PHILIPS MEDICAL SYSTEM (CLEVELAND) INC, UNITED States. PRODUCT'S REGISTRATION (AKL/AKD) KEMENKES RI AKL 21501410809 REFERENCE OF TECHNICAL X-Ray Tube & Generator Anode effctive heat capacity 30 MHU; direct cooling Anode Heat Storage Capacity 8 MHU Anode cooling rate 1,608KHU/min Large focal spot size 1.0mm x 1.0mm Small focus spot size 0.5mm x 1.0mm Segmented Anode Yes Tube cooling system Air cooled Direct Anode cooling Yes Spiral groove bearing Yes Maximum helical exposure time 100 sec Generator power 80 kW KV selections 80, 100, 120 & 140kV mA Range 20 - 665 mA Technology Low dose with Higher Image quality Improvement in spatial resolution and or reduction at low dose (iterative reconstruction) Yes , iDose4 Generation of Reconstruction Generation 4 Significantly lower dose while simultaneously improving image quality yes Significantly improved spatial resolution (low noise / low-contrast detectability / spatial resolution) yes Signifiantly improved image quality (lower noise,improved low contrast, improved resolution) Yes Metal artifact reduction for large orthopedic implant (OMAR) Improves image quality through artifact prevention and increased spatial resolution at low dose, and reduces artifacts caused by large orthopedic implants Yes, OMAR New Technology for Scanning Automatic collimation after surview /topogram yes, with ipatient technology The system will automatically determine the optimal rotation time, pitch and collimation to deliver the best results automatically yes, with ipatient technology Plan the results, not the acquisition yes, with ipatient technology Facilitates optimal** management of image quality and radiation dose with patient-specifi methods yes, with ipatient technology CT Dose Check notification on parameter and radiation dose with patient- specific methods yes, with ipatient technology Dose Management Adhere to ALARA Principles Yes. DoseWise Principles ACS (Automatic Current Selection) DoseRight ACS Dynamic Dose Modulation (DDOM) DoseRight D-DOM z-axis Dose Modulation (zDOM) DoseRight z-DOM Display of CTDIvol and DLP during planning Yes. Dedicated Pediatric Protocols Yes. GANTRY Gantry Aperture 70 cm 360° Rotation Speeds 0.4 sec for full 360o scan, Effctive cardiac rotation time 0.3 seconds Slices 128 Gantry controls on right and left of gantry Yes Gantry controls on front and back of gantry Yes Maximum Scan FOV 50cm 25 & 50 cm Tilt ± 30° in 0.5° increment Gantry Cooling Method Air Cooling Laser positioning lights Yes Intercom system Yes DETECTOR Solid State CT Detector Yes, Gadilinium Oxisulfide (GOS) Number of detector rows 64 Number of slice per rotation 128 Transfer rate (speed) of slip ring 5.3 Gbytes/sec Data sampling rate 4640 views/rev/element Slice collimations 64 x 0.625mm, 40 x 0.625 mm, 20 x 0.625 mm, 16 x 0.625 mm, 12 x 0.625 mm, 8 x 0.625 mm, 4 x 0.625 mm, 2 x 0.625 mm, 32 x 1.25 mm, 12 x1.25mm Area coverage per scan rotation 40 mm Reconstruction and Image Quality Recon FOV 5-50cm Standard reconstruction matrix 512 x 512 Ultra High reconstruction matrix 768 x 768 & 1024 x 1024 matrix Spatial Resolution 24 lp/cm Noise 0.27% Absorption Range -1024 to +3071 Hounsfield units Standard reconstruction speed 25 image /sec Adaptive multicycle reconstruction for Cardiac Yes Temporal resolution 0.053 sec Patient Table Sannable range 1750 mm Longitudinal speed 0.5-185 mm/sec Z- position accuracy ± 0.25 mm Remote Table control from Console yes, up/down, in/out Scanner Console Operating System Windows Screen size (diagonal) 19" Monitor 2 x LCD monitor Resolution 1280 x 1024 Remote control from console Dicom DICOM 3.0 configuration, DICOM print/store, DICOM send Dicom CD writer yes Filming yes Scan time showed on console yes CT Dose Index showed on console yes Dose Length Product showed on console yes Scanner User Environment Combined acquisition and image processing console Comply Scan control Box Comply Two-way Intercom System Comply Bolus Tracking - Track constrast medium to trigger scanning using multiple ROI Comply Automated Contrast bolus triggering Yes Prospective ECG gating /triggering Yes Retrospective tagging Yes Adaptive multi-cycle reconstruction algorithm Yes Integrated ECG Monitor Yes Cardiac Viewer Yes CT Reporting Yes Dose management Yes Image Processing/Review Slab Viewer yes Cursor for pixel value measurements yes Angle measurements yes Double Window: Simultaneous displays of two independent CT density ranges on the same image yes Invert Window yes RelateSlice yes 3D Small Volume Analysis yes Curved MPR viewing yes 3D display viewing yes Volume rendering viewing yes Maximum Intensity Projection (MIP) yes Minimum Intensity Projection (minIP) yes Volume Intensity Projection (VIP) yes ROI yes Volume Calculation yes CT Number Display yes cine yes Workstation (ISP) Operating system Windows series Memory 16GB MPR Yes Available planes in multi planar reformatting 5 planes includes orthogonal, axial, sagittal, coronal, curved MIP and mMIP Yes Small volume analysis to measure tumors and/ or organ Yes Support of external USB 2.0 data storage devices Yes Medium DVD/CD-RW Yes Tool to show survey scan as localizer for multi planar reformatting display Yes Function to displays a moveable, mini-window which can be set with its own windowing, image enhancement and rendering parameters to enhance visualization and assessment of certain elements of the image, while maintaining optimal viewing parameters for the main viewport Yes Windowing presets Yes CT Comprehensive Cardiac Analysis Yes Application to assess the state of the coronary arteries and to analyze functional heart data Tools to performs a full segmentation procedure, segmented entire organ at one time based on a pre-defined model Number of segmentation model Tools to view details of the segmentation, make manual corrections, save the segmentation, and apply a new segmentation algorithm Tools to perform quantitative measurements concerning the coronary arteries as percent stenosis and cross-sectional area based on automatic lumen contouring or manual methods Able to display ECG Graphic Able to shows the heart with blood in the cavities removed as MIP Able to shows a 2D Cartesian display of the heart’s surface Tools to shows a MIP image of the heart’s surface based on the coronarycenterlines in true anatomic orientation of the heart Tools to shows a 3D map mapped onto a sphere as MIP Automatic contours tools Yes, With Comprehensive Cardiac Analysis CT Functional Analysis Cardiac yes, with CCA CT Calcium Scoring yes CT Angio Yes CT Automatic bone removal - cranial Yes CT Automatic bone removal - CTA Yes CT Virtual Colonoscopy Yes CT Brain Perfusion Yes, With Advanced Brain Perfusion The package should generates quantitative color maps of cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT) and time- to-peak (TTP), in addition to summary maps. Yes CT Brain Perfusion with Summary Map Yes, With Advanced Brain Perfusion to differentiates areas of increased blood volume and decreased blood flow and presents this information in a summary map to help clinicians distinguish between still-viable and non-viable infarcted tissue. Yes CT Advanced vessel analysis Yes Application for general vascular analysis and stent planning from body and skull (head and neck) studies Able to perform automatic vessel centerline extraction Able to perform automatic vessel labeling of major vessels Allows visualization of calcium in the vessels Head vessel name list Functions to allows to add vertices beyond the distal and proximal ends of the extracted vessel centerline, and select which end will be continued from Function to allows to view in a semitransparent mode all volumetric anatomy that has been removed included anatomy removed automatically and manually Yes, with AVA CT Advanced Vessel Analysis - Stent Planning Yes Stent Planning Packages with Auto centerline detection tools to provide the basis for accurate reproducible quantitative measurements of vascular structures for planning endoluminal stent to repair aneurysms, stenosis and other vascular abnormalities Yes, with AVA Stent Palnning Liver Analysis Package segmentation tools to facilitate for assessing the liver, hepatic vasculature of individual vascular segments, and physician-identified lesions Yes, With Liver Analysis Able to Perform segmentation of the liver tissue, vessels, and lesions Mode of Liver Segments selections to determine Able to determine 8 segments Coinaud Able to determine 9 segments Bismuth Available list of segments to place landmark seeds The application enables absolute and relative volume measurements as well as virtual hepatectomy for RF ablation and surgery planning. CT Lung Nodule Assestment yes, with Lung Nodule Assestment for volumetric analysis of pulmonary nodule or lesion size over time, and to accurately assess the nodule's doubling time growth rate. Yes CT Virtual Endoscopy Yes, comply CT Viewer Yes, comply CT Reporting Yes, comply with reporting capabilities for paper print of clinical results including display of key images and results frames. Yes

Specifications

ConditionUsed
Name of productMultislice CT Scan 128 SLICE
Brand/ manufacturerPhilips
Model / typeINGENUITY CORE 128
Factory of originPHILIPS HEALTHCARE (SUZHOU) Co.,Ltd,. CHINA Melalui PHILIPS MEDICAL SYSTEM (CLEVELAND) INC, UNITED States.
Product's registration (akl/akd)KEMENKES RI AKL 21501410809
Anode effctive heat capacity30 MHU; direct cooling
Anode heat storage capacity8 MHU
Anode cooling rate1,608KHU/min
Large focal spot size1.0mm x 1.0mm
Small focus spot size0.5mm x 1.0mm
Segmented anodeYes
Tube cooling systemAir cooled
Direct anode coolingYes
Spiral groove bearingYes
Maximum helical exposure time100 sec
Generator power80 kW
Kv selections80, 100, 120 & 140kV
Ma range20 - 665 mA
Improvement in spatial resolution and or reduction at low dose (iterative reconstruction)Yes , iDose4
Generation of reconstructionGeneration 4
Significantly lower dose while simultaneously improving image qualityyes
Significantly improved spatial resolution (low noise / low-contrast detectability / spatial resolution)yes
Signifiantly improved image quality (lower noise,improved low contrast, improved resolution)Yes
Improves image quality through artifact prevention and increased spatial resolution at low dose, and reduces artifacts caused by large orthopedic implantsYes, OMAR
Automatic collimation after surview /topogramyes, with ipatient technology
The system will automatically determine the optimal rotation time, pitch and collimation to deliver the best results automaticallyyes, with ipatient technology
Plan the results, not the acquisitionyes, with ipatient technology
Facilitates optimal** management of image quality and radiation dose with patient-specifi methodsyes, with ipatient technology
Ct dose check notification on parameter and radiation dose with patient- specific methodsyes, with ipatient technology
Adhere to alara principlesYes. DoseWise Principles
Acs (automatic current selection)DoseRight ACS
Dynamic dose modulation (ddom)DoseRight D-DOM
Z-axis dose modulation (zdom)DoseRight z-DOM
Display of ctdivol and dlp during planningYes.
Dedicated pediatric protocolsYes.
Gantry aperture70 cm
360° rotation speeds0.4 sec for full 360o scan, Effctive cardiac rotation time 0.3 seconds
Slices128
Gantry controls on right and left of gantryYes
Gantry controls on front and back of gantryYes
Maximum scan fov 50cm25 & 50 cm
Tilt± 30° in 0.5° increment
Gantry cooling methodAir Cooling
Laser positioning lightsYes
Intercom systemYes
Solid state ct detectorYes, Gadilinium Oxisulfide (GOS)
Number of detector rows64
Number of slice per rotation128
Transfer rate (speed) of slip ring5.3 Gbytes/sec
Data sampling rate4640 views/rev/element
Slice collimations64 x 0.625mm, 40 x 0.625 mm, 20 x 0.625 mm, 16 x 0.625 mm, 12 x 0.625 mm, 8 x 0.625 mm, 4 x 0.625 mm, 2 x 0.625 mm, 32 x 1.25 mm, 12 x1.25mm
Area coverage per scan rotation40 mm
Recon fov5-50cm
Standard reconstruction matrix512 x 512
Ultra high reconstruction matrix768 x 768 & 1024 x 1024 matrix
Spatial resolution24 lp/cm
Noise0.27%
Absorption range-1024 to +3071 Hounsfield units
Standard reconstruction speed25 image /sec
Adaptive multicycle reconstruction for cardiacYes
Temporal resolution0.053 sec
Sannable range1750 mm
Longitudinal speed0.5-185 mm/sec
Z- position accuracy± 0.25 mm
Remote table control from consoleyes, up/down, in/out
Operating systemWindows series
Screen size (diagonal)19"
Monitor2 x LCD monitor
Resolution1280 x 1024
Remote control from consoleTable: Up/down, In/out
DicomDICOM 3.0 configuration, DICOM print/store, DICOM send
Dicom cd writeryes
Filmingyes
Scan time showed on consoleyes
Ct dose index showed on consoleyes
Dose length product showed on consoleyes
Combined acquisition and image processing consoleComply
Scan control boxComply
Two-way intercom systemComply
Bolus tracking - track constrast medium to trigger scanning using multiple roiComply
Automated contrast bolus triggeringYes
Prospective ecg gating /triggeringYes
Retrospective taggingYes
Adaptive multi-cycle reconstruction algorithmYes
Integrated ecg monitorYes
Cardiac viewerYes
Ct reportingYes, comply
Dose managementYes
Slab vieweryes
Cursor for pixel value measurementsyes
Angle measurementsyes
Double window: simultaneous displays of two independent ct density ranges on the same imageyes
Invert windowyes
Relatesliceyes
3d small volume analysisyes
Curved mpr viewingyes
3d display viewingyes
Volume rendering viewingyes
Maximum intensity projection (mip)yes
Minimum intensity projection (minip)yes
Volume intensity projection (vip)yes
Roiyes
Volume calculationyes
Ct number displayyes
Cineyes
Memory16GB
MprYes
Available planes in multi planar reformatting5 planes includes orthogonal, axial, sagittal, coronal, curved
Mip and mmipYes
Small volume analysis to measure tumors and/ or organYes
Support of external usb 2.0 data storage devicesYes
Medium dvd/cd-rwYes
Tool to show survey scan as localizer for multi planar reformatting displayYes
Function to displays a moveable, mini-window which can be set with its own windowing, image enhancement and rendering parameters to enhance visualization and assessment of certain elements of the image, while maintaining optimal viewing parameters for the main viewportYes
Windowing presetsYes
Ct comprehensive cardiac analysisYes
Application to assess the state of the coronary arteries and to analyze functional heart data tools to performs a full segmentation procedure, segmented entire organ at one time based on a pre-defined model number of segmentation model tools to view details of the segmentation, make manual corrections, save the segmentation, and apply a new segmentation algorithm tools to perform quantitative measurements concerning the coronary arteries as percent stenosis and cross-sectional area based on automatic lumen contouring or manual methods able to display ecg graphic able to shows the heart with blood in the cavities removed as mip able to shows a 2d cartesian display of the heart’s surface tools to shows a mip image of the heart’s surface based on the coronarycenterlines in true anatomic orientation of the heart tools to shows a 3d map mapped onto a sphere as mip automatic contours toolsYes, With Comprehensive Cardiac Analysis
Ct functional analysis cardiacyes, with CCA
Ct calcium scoringyes
Ct angioYes
Ct automatic bone removal - cranialYes
Ct automatic bone removal - ctaYes
Ct virtual colonoscopyYes
Ct brain perfusionYes, With Advanced Brain Perfusion
The package should generates quantitative color maps of cerebral blood flow (cbf), cerebral blood volume (cbv), mean transit time (mtt) and time- to-peak (ttp), in addition to summary maps.Yes
Ct brain perfusion with summary mapYes, With Advanced Brain Perfusion
To differentiates areas of increased blood volume and decreased blood flow and presents this information in a summary map to help clinicians distinguish between still-viable and non-viable infarcted tissue.Yes
Ct advanced vessel analysisYes
Application for general vascular analysis and stent planning from body and skull (head and neck) studies able to perform automatic vessel centerline extraction able to perform automatic vessel labeling of major vessels allows visualization of calcium in the vessels head vessel name list functions to allows to add vertices beyond the distal and proximal ends of the extracted vessel centerline, and select which end will be continued from function to allows to view in a semitransparent mode all volumetric anatomy that has been removed included anatomy removed automatically and manuallyYes, with AVA
Ct advanced vessel analysis - stent planningYes
Stent planning packages with auto centerline detection tools to provide the basis for accurate reproducible quantitative measurements of vascular structures for planning endoluminal stent to repair aneurysms, stenosis and other vascular abnormalitiesYes, with AVA Stent Palnning
Segmentation tools to facilitate for assessing the liver, hepatic vasculature of individual vascular segments, and physician-identified lesionsYes, With Liver Analysis
Ct lung nodule assestmentyes, with Lung Nodule Assestment
For volumetric analysis of pulmonary nodule or lesion size over time, and to accurately assess the nodule's doubling time growth rate.Yes
Ct virtual endoscopyYes, comply
Ct viewerYes, comply
With reporting capabilities for paper print of clinical results including display of key images and results frames.Yes
TableUp/down, In/out