GE 9900 Elite PM Care C-Arm
GE 9900 Elite PM Care C-Arm
Description
2017 GE 9900 Elite PM Care C-Arm
12-Inch Image Intensifier.
Very Low Usage System.
PM Care Platform includes:
1000 image storage
Zoom and roam function
Image annotation & Measurement software
8-Frames Per Second Dynamic digital disk
Recording/playback rate: 1, 2, 4, 8fps
Frame-by-frame review
Recording time: 5 minutes @ 8fps
Real-time subtraction
Digital subtraction (DSA) angiography
Peak opacification
Ready to ship
60 kHz high frequency.
15 kW full-wave.
Up to 120 kVp.
Up to 75 mA for radiographic film exposure.
Continuous high level fluoro up to 20 mA.
Pulsed fluoro mode.
Pulsed fluorography mode up to 40 mA.
Digital spot up to 75 mA.
Full power from outlet:
50 Hz or 60 Hz.
120V-12A or 240V-10A.
Rotating anode X-ray tube.
Standard housing cooling 15,000 HU/min.
Passive housing cooling system: 22,500 HU/min. (Standard on 12 inch (31 cm) I.I. systems.
On-screen collimator position indication.
PreView™ iris collimator.
PreView™ Tungsten rotatable double leaf collimator.
Adjusts collimators without X-ray exposure.
Auto and manual fluoro modes.
Continuous, one-shot or pulsed operation.
AutoTrak™ ABS varies mA, kVp, camera gain.
AutoTrak™ ABS, mA, kVp, camera gain.
Reduces X-ray dose to patient and operator.
AutoTrak™ ABS, mA, kVp, and camera gain.
Automatic exposure termination and automatic image save.
High resolution 1k x 1k CCD camera.
Full frame capture.
Motorized rotation.
On-screen orientation indicator. (real-time feedback without fluoro.)
Left-right image reversal.
Top-bottom image reversal.
Dual 18” (46cm) display anti-glare, LCD flat panel monitors mounted on an articulating arm.
22” horizontal travel.
7° up/10° down.
Monitors viewable from all four sides of workstation.
Horizontal and vertical viewing angle 170°.
700 CD/M2 maximum brightness.
Touch screen system control.
1280 x 1024 high resolution monitors.
Ambient room-light compensation.
Integrated color monitor for display of VGA, DVI, DVI-D, S-VHS.
12-Inch Image Intensifier.
Very Low Usage System.
PM Care Platform includes:
1000 image storage
Zoom and roam function
Image annotation & Measurement software
8-Frames Per Second Dynamic digital disk
Recording/playback rate: 1, 2, 4, 8fps
Frame-by-frame review
Recording time: 5 minutes @ 8fps
Real-time subtraction
Digital subtraction (DSA) angiography
Peak opacification
Ready to ship
60 kHz high frequency.
15 kW full-wave.
Up to 120 kVp.
Up to 75 mA for radiographic film exposure.
Continuous high level fluoro up to 20 mA.
Pulsed fluoro mode.
Pulsed fluorography mode up to 40 mA.
Digital spot up to 75 mA.
Full power from outlet:
50 Hz or 60 Hz.
120V-12A or 240V-10A.
Rotating anode X-ray tube.
Standard housing cooling 15,000 HU/min.
Passive housing cooling system: 22,500 HU/min. (Standard on 12 inch (31 cm) I.I. systems.
On-screen collimator position indication.
PreView™ iris collimator.
PreView™ Tungsten rotatable double leaf collimator.
Adjusts collimators without X-ray exposure.
Auto and manual fluoro modes.
Continuous, one-shot or pulsed operation.
AutoTrak™ ABS varies mA, kVp, camera gain.
AutoTrak™ ABS, mA, kVp, camera gain.
Reduces X-ray dose to patient and operator.
AutoTrak™ ABS, mA, kVp, and camera gain.
Automatic exposure termination and automatic image save.
High resolution 1k x 1k CCD camera.
Full frame capture.
Motorized rotation.
On-screen orientation indicator. (real-time feedback without fluoro.)
Left-right image reversal.
Top-bottom image reversal.
Dual 18” (46cm) display anti-glare, LCD flat panel monitors mounted on an articulating arm.
22” horizontal travel.
7° up/10° down.
Monitors viewable from all four sides of workstation.
Horizontal and vertical viewing angle 170°.
700 CD/M2 maximum brightness.
Touch screen system control.
1280 x 1024 high resolution monitors.
Ambient room-light compensation.
Integrated color monitor for display of VGA, DVI, DVI-D, S-VHS.
Caractéristiques
Année | 2017 |
Condition | D'occasion |
Focal spots | 0.3 mm and 0.6 mm. |
Anode heat capacity | 300,000 HU. |
Anode cooling rate | 85,000 HU/min. |
Housing heat capacity | 1,600,000 HU. |
Focal spot | 0.3 mm. |
Kvp range | 40 – 120 kVp. |
Ma range | Up to 75 mA. |
Pulse rate | 1, 2, 4, or 8 pulses per second. |
Pulse width | 25 or 50 milliseconds. |
Vp range | 40 – 120 kVp. |
Height | 69.7 / 87.7 in. (1770 / 2228 mm.) |
Width | 33.5 in. (851 mm.) |
Length | 77.8 in. (1976 mm.) |
Weight | 610 lbs. (277 kg.) |