Philips BV-300 Plus C-Arm
Philips BV-300 Plus C-Arm
Description
***PARTS ONLY***
Tri-mode Image Intensifier /span>
Dual High Resolution Monitors
Options:
Vascular Application
Tri-Mode 12"/9/6 II
Has a Rotating Anode
Specifications:
X-Ray System
Specialty Packages Available
• Extended processing
• Vascular functions
• Extended vascular functions
Generator
• 2.1 kW full-wave
• Up to 110 kVp
• Up to 20 mA for radiographic film exposures
• Continuous fluoro boost mode up to 7.3 mA
• Full power from outlet:
- 50 Hz or 60 Hz
- 100V-15A to 240V-10A
X-Ray Tube
• Fixed anode X-ray tube
Collimator
• Iris collimation with dual opposing lead shutters allowing elliptical, round and rectangular collimation
• Minimum beam size < 5 X 5 cm2
• Iris and shutters are continuously variable
• All functions remotely controlled from the C-Arm control panel
Fluoroscopy Mode
• Auto and manual modes
• Continuous or Pulsed operation
• APF varies mA, kVp and camera gain
• User specific APF tables
Pulsed Fluoroscopy Mode (optional)
• Computer controlled APF, mA, kVp and camera gain
Pulsed Fluorography Mode (optional)
• Computer controlled camera iris, mA, kVp, & camera gain
Radiographic Mode
• Fixed 20 mA
Video Imaging System
Image Intensifier
9 in Image Intensifier
• Tri-mode 9 in / 7 in / 5 in image intensifier
12 in Image Intensifier (optional)
• Tri-mode 12 in / 9 in / 7 in image intensifier
Video Camera
• High resolution CCD camera
• 525 line/frame
• 360° motorized rotation
• Left-right image reversal
• Top-bottom image reversal
• Negative mode
- Gain
- Blanking
- Camera iris
Video Monitors
• Dual 17 in standard resolution, anti-glare, anti-static
• Ambient room light sensor
• Multi-LED X-ray "ON" indicator
Hardcopy Options
• Thermal printer (optional)
• DICOM (optional)
• Image Capture Device (optional)
C-Arm Dimensions
Workstation Dimensions
Caractéristiques
Condition | D'occasion |
• focal spots | 0.6 mm and 1.4 mm |
• anode heat capacity | 50,100 HU |
• anode cooling rate | 20,200 HU/min |
• housing heat capacity | 1,200,000 HU |
• anode angle | 12° |
• focal spot | 1.4 mm |
• kvp range | 40 – 105 kVp |
• ma range | Up to 60 mA |
• pulse rate | 3 to 30 pulses per second (optional) |
• pulse width | 8.0 / 9.5 / 11.1 milliseconds |
- 9 in. | 1.6 lp/mm |
- 7 in. | 2.2 lp/mm |
- 5 in. | 2.9 lp/mm |
• dqe | 65% (typical) |
- 12 in. | 1.2 lp/mm |
• computer controlled features | (optional) |
• height | 69 in (1760 mm) |
• width | 37 in (930 mm) |
• length | 72 in (1840 mm) |
• weight | 463 lbs 210 kg |
• depth | 37 in (760 mm) |